Worcester Greenstar EA Fault Repair
Heat exchanger strip clean and replacement electrodes
The Brief
The customer's Worcester Greenstar 30CDi was showing an EA fault code, which on a Worcester boiler means it has tried to light and failed to detect a flame.
What We Did
Our repair included:
- Fault finding: we confirmed the EA ignition fault.
- Heat exchanger strip clean: the heat exchanger was stripped down and cleaned to clear the build-up.
- New electrodes: the old ignition and flame-sensing electrodes were scaled, so we replaced them with a new set.
- Reassembly and testing: the boiler was rebuilt and tested.
The Result
With the heat exchanger strip-cleaned and new electrodes fitted, the boiler was back up and running. An annual service helps catch this kind of build-up before it leads to a breakdown.